Operation CHARM: Car repair manuals for everyone.

System Specifications

FAST IDLE VALVE
Operating temp. (coolant) Below 86 degrees F (30 degrees C)

FUEL PUMP
OPERATING PRESSURE 50 psi (343 kPa)
CAPACITY 333 cc/min
RELIEF VALVE PRESSURE 71-92 psi (490-637 kPa)

FUEL REGULATOR PRESSURE [1] 47-53 psi (323-363 kPa)

[1] Vacuum hose disconnected