Shift Forks Clearance Inspection
InspectionNOTE: The synchro sleeve and synchro hub should be replaced as a set.
1. Measure the clearance between each shift fork (A) and its matching synchro sleeve (B). If the clearance exceeds the service limit, go to step 2.
2. Measure the thickness of the shift fork fingers.
- If the thickness of the shift fork finger is not within the standard, replace the shift fork with a new one.
- If the thickness of the shift fork finger is within the standard, replace the synchro sleeve with a new one.
3. Measure the clearance between the shift fork (A) and the shift arm (B). If the clearance exceeds the service limit, go to step 4.
NOTE: 6-speed model is shown.
4. Measure the width of the shift arm.
- If the width of the shift arm is not within the standard, replace the shift arm with a new one.
- If the width of the shift arm is within the standard, replace the shift fork or shift piece with a new one.