Passenger's Cool Vent Control Motor Test
Passenger's Cool Vent Control Motor TestNOTE: Before testing, check for HVAC DTCs.
1. Disconnect the 5P connector from the passenger's cool vent control motor.
NOTICE:
Incorrectly applying power and ground to the passenger's cool vent control motor will damage it. Follow the instructions carefully.
2. Connect battery power to the No. 1 terminal of the passenger's cool vent control motor, and ground the No. 2 terminal; the passenger's cool vent control motor should run, and stop at Shut. If it doesn't, reverse the connections; the passenger's cool vent control motor should run, and stop at Open.
3. If the passenger's cool vent control motor did not run in step 2, remove it, then check the passenger's cool vent control linkage and door for smooth movement.
- If the linkage and door move smoothly, replace the passenger's cool vent control motor.
- If the linkage or door sticks or binds, repair them as needed.