CMBS Off Switch Test/Replacement (With ACC/CMBS)
CMBS OFF Switch Test/Replacement
1. Remove the instrument fascia. Instrument Fascia Removal/Installation
2. Remove the screws and the multi-switch (A).
3. Check for continuity between the terminals in each CMBS OFF switch position according to the table.
4. If the continuity is not as specified, replace the switch.