Door Lock Switch Test
Door Lock Switch Test
1. Remove the door panel. Front Door Panel Removal/Installation
2. Disconnect the 4P connector (A), remove the two screws, then remove the door lock switch (B).
3. Check for continuity between the terminals.
- There should be continuity between the terminals No. 2 and No. 4 when the door lock switch is in the LOCK position.
- There should be no continuity between the terminals No. 2 and No. 4 when the door lock switch is in the neutral position or UNLOCK position.
- There should be continuity between the terminals No. 2 and No. 3 when the door lock switch is in the UNLOCK position.
- There should be no continuity between the terminals No. 2 and No. 3 when the door lock switch is in the neutral position or LOCK position.
- There should be continuity between the terminals No. 1 (+) and No. 2 (-) (bulb check).
4. If the continuity is not as specified, replace the bulb or switch.