VSA Activation Indicator Does Not Come on at Start-Up (Bulb Check)
Symptom Troubleshooting: VSA activation indicator does not come on at start-up (bulb check)
VSA activation indicator does not come on at start-up (bulb check)
1. Turn the ignition switch to ON (II), and watch the VSA activation indicator.
Does the VSA activation indicator come on for several seconds?
YES - The system is OK at this time. Refer to intermittent failures. Initial Inspection and Diagnostic Overview
NO - Go to step 2.
2. Apply the parking brake.
Does the brake system indicator come on?
YES - Go to step 3.
NO - Repair open in the gauge control module indicator power source circuit.
3. Turn the ignition switch to LOCK (0).
4. Substitute a known-good VSA modulator-control unit. Service and Repair
5. Turn the ignition switch to ON (II).
Does the VSA activation indicator come on?
YES - Replace the VSA modulator-control unit. Service and Repair
NO - Do the troubleshooting for the gauge control module. How to Troubleshoot the Gauges and Indicators