Engine Controls - Hard Start/Long Crank After Hot Soak
09-007July 22, 2011
Applies To:
2009 RL - From VIN JH4KB26..9C000001 thru JH4KB26..9C001588
Long Crank Time or Hard Start After "Hot/Warm Soak"
(Supercedes 09-007, dated February 7, 2009, to update the information marked by the black bars).
REVISED SUMMARY
SYMPTOM
The engine cranks a long time before starting after a 30-minute to 8-hour "soak" period (engine shut off after running at normal temperature).
PROBABLE CAUSE
The intake manifold oxygen concentration is lower than expected.
CORRECTIVE ACTION
Update the PGM-FI software with the HDS.
SOFTWARE INFORMATION
HDS Software Version: 2.016.015 or later.
Control Module (CM) Update:
Application Version V6.14.06 or later.
Database Update 18-DEC-2008 or later.
NOTE:
To avoid an incorrect repair that would not be covered under warranty, use the software version listed above or a later version.
The updated PGM-FI software program ID and P/N is shown. If this, or a later program ID, is the Current Program ID displayed during the update, the software for this service bulletin is already installed.
WARRANTY CLAIM INFORMATION
REPAIR PROCEDURE
Update the PGM-FI software with the HDS. Refer to Service Bulletin 01-026, Updating Control Units/ Modules.
Disclaimer