Suspension Stroke Sensor Test (With AFS)
Suspension Stroke Sensor Test
1. Remove the suspension stroke sensor. Suspension Stroke Sensor Replacement (With AFS)
2. Measure the resistance between the suspension stroke sensor 3P connector terminals No. 1 and No. 3. There should be about 3.5-6.5 kOhms.
3. Measure the resistance between the suspension stroke sensor 3P connector terminals No. 2 and No. 3 with the linkage (A) moved. There should be about 0.5-4.5 kOhms.
4. If the resistance is not as specified, replace the suspension stroke sensor.
5. After replacement, do the adaptive front lighting control unit learning procedure. Adaptive Front Lighting Control Unit Learning Procedure - When a Brand New Front Lighting Control Unit is Installed