The A/C Compressor Relief Valve Has Vented Refrigerant
The A/C compressor relief valve has vented refrigerant
Diagnostic Procedure:
1. Probable cause: A high-side restriction, the A/C condenser/radiator fans are inoperative, or the A/C compressor clutch is not disengaging
2. If the fans and compressor clutch operate normally, recover refrigerant, A/C Refrigerant Recovery and check for restrictions
3. If the compressor clutch will not disengage, troubleshoot the clutch circuit, A/C Compressor Clutch Circuit Troubleshooting and check for mechanical problems Testing and Inspection
4. If the fans are inoperative, troubleshoot the fan circuits A/C Condenser Fan Circuit Troubleshooting (Open)
Also check for:
- Powertrain DTCs Reading and Clearing Diagnostic Trouble Codes