The A/C Condenser/Radiator Fans Do Not Run at High Speed, But Do Run at Low Speed
The A/C condenser/radiator fans do not run at high speed, but do run at low speed
The A/C condenser/radiator fans do not run at high speed, but do run at low speed
Probable cause: Malfunction in the fan(s) high speed circuit.
Do the following troubleshooting as needed:
A/C condenser fan high speed circuit troubleshooting A/C Condenser Fan High Speed Circuit Troubleshooting
Radiator fan high speed circuit troubleshooting Radiator Fan High Speed Circuit Troubleshooting
Probable cause: A/C pressure sensor circuit malfunction.
Do the A/C pressure sensor troubleshooting:
A/C pressure sensor circuit low voltage A/T
A/C pressure sensor circuit high voltage A/T
NOTE: The A/C pressure sensor can malfunction without setting a DTC
Also Check for
Climate control DTCs
Also Check for
Powertrain DTCs
Also Check for
Blown fuse No. 5 (20 A) in the under-hood fuse/relay box
Also Check for
Poor ground at G301
Also Check for
Poor or loose connections at the terminals