Low Fuel Lamp/Indicator: Service and Repair
Adaptation (Scan Tool Function 10)
Instrument cluster
Function 10 is used to initiate and store the following changes:
- Adaptation of fuel the consumption indicator
- Coding of language version for the driver information display and Auto Check system
- Adaptation of the Service Reminder Indicator (SRI)
- Adaptation of the odometer replacement of the instrument cluster
- Adaptation of fuel gauge sender resistance range
The individual functions are called up by entering the appropriate adaptation channel numbers listed in the adaptation table.
Adaptation table
Adaptation channel Adaptation function
02 Resetting Service Reminder Indicator (SRI) after a service
03 Adapting fuel consumption indicator
04 Language versions for driver information system
05 SRI: service interval for oil change service
06 SRI: service interval for inspection service (distance)
07 SRI: service interval for inspection service (time)
09 Odometer
10 SRI: distance remaining until next oil change service after replacing instrument cluster
11 SRI: distance remaining until next inspection service after replacing instrument cluster
12 SRI: time remaining until next inspection service after replacing instrument cluster
30 Adapting fuel gauge sender resistance range
Initiating "Adaptation" function 10
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -1- and -0- to select "Adaptation" function 10.
- Press -Q- button to confirm input.
Indicated on display
Adaptation
Insert channel number XX
- Insert required adaptation channel number See adaptation table.
- Press -Q- button to confirm input.
NOTE: After an adaptation value has been changed, or adaptation in a specific channel has been completed, "Adaptation" function 10 must be selected again in order to select another adaptation channel.
Adapting fuel consumption indicator
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -1- and -0- to select "Adaptation" function 10.
- Press -Q- button to confirm input.
Indicated on display
Adaptation
Insert channel number XX
- Press buttons -0- and -3- to insert channel number 03.
- Press -Q- button to confirm input.
NOTE:
- Adaptation is only possible on vehicles with the driver information display.
- The value entered must be between 85% and 115%.
- The value must be entered in steps of 5%.
Indicated on display
Channel 3 Adaptation 100 ->
<-13->
- Press -> button.
NOTE: The fuel consumption indicator can only be adapted using direct input.
Indicated on display
Channel 3 Adaptation 100
Input adaptation value XXXXX
- Input required adaptation value using keypad on VAG 1551 scan tool, filling in initial spaces with "0."
Example:
Required value: 90%
- Input "00090" using keypad.
Indicated on display
Channel 3 Adaptation 100 Q
Input adaptation value 00090
- Press -Q- button to confirm input.
Indicated on display
Channel 3 Adaptation 90 Q
Store changed value?
- Press -Q- button to confirm input.
Indicated on display
Channel 3 Adaptation 90 ->
Changed value is stored
- Press -> button to complete fuel consumption indicator adaptation.
Indicated on display
Rapid data transfer HELP
Select function XX
If an incorrect entry is made the VAG1551 or VAG1552 Scan Tool (ST) will switch to the following display.
Function is unknown or ->
cannot be carded out at the moment
- Press -> button.
- Select "Adaptation" function 10 and adaptation channel number 03 again.
- Repeat adaptation of fuel consumption indicator.
- Confirm entry with -Q- button.