Combination Valve For Secondary Air Injection (AIR), Checking Function and Proper Seal
Combination Valve For Secondary Air Injection (AIR), Checking Function And Proper Seal
Special tools and equipment
- VAG1390 Hand vacuum pump
Requirements
- Vacuum lines and hose connections leak-free.
- Vacuum lines not clogged.
Work sequence
- Remove rear engine cover (arrows).
- Remove bolts for holding plate for solenoid valves (arrows).
- Lift up holding plate and disconnect vacuum hose from Y-piece of combination valve to be checked.
- Connect VAG1390 hand vacuum pump to vacuum hose of combination valve to be checked.
- For vehicles with auxiliary heater, remove bolts (arrows) for exhaust pipe of auxiliary heater at sound insulation.
- Remove bolts or release quick-release screws -1- and -2- and remove front sound insulation.
- Disconnect pressure hose (arrow) at Secondary Air Injection (AIR) pump motor and blow into it with light pressure (do not use pressurized air).
- Both combination valves must be closed, it must not be possible to blow through hose
- Operate hand vacuum pump.
- Relevant combination valve must open, it must be possible to blow through
If the relevant combination valve does not open:
- Replace combination valve.
With Manufacturer's Scan Tool
Combination Valves For Secondary Air Injection (AIR) System, Checking Function And For Proper Seal
Recommended special tools and equipment
- VAG1390 Hand Vacuum Pump
Test requirements:
- No leaks in vacuum lines or hose connections.
- Vacuum lines not clogged.
Test sequence
- Remove rear engine cover (arrows).
- Remove bolts for holding plate for solenoid valves (arrows).
- Lift up holding plate and disconnect vacuum hose from Y-piece of combination valve to be checked.
- Connect e.g. V.A.G 1390 hand vacuum pump to vacuum hose of combination valve to be checked.
- Remove bolts or quick-release screws -1- and -2- and remove front sound insulation.
- Disconnect pressure hose (arrow) at Secondary Air Injection (AIR) pump motor and blow air in with light pressure (do not use pressurized air).
- Both combination valves must be closed, it must not be possible to blow through hose
- Operate hand vacuum pump.
- The relevant combination valve must open, it must not be possible to blow through
If respective combination valve does not open:
- Replace combination valve.
Final procedures
After repair work, the following work steps must be performed in the mentioned sequence:
1. Check DTC memory. Diagnostic Mode 03 - Read DTC Memory
2. If necessary, erase DTC memory. Diagnostic Mode 04 - Erase DTC Memory
3. If DTC memory was erased, generate readiness code.
- End diagnosis and switch ignition off.