P0332
System/ComponentKnock Sensor
Fault Code
P0332 (cylinder 4-6)
Fault Type
Plausibility Yes
Signal No
Minimum Threshold No
Maximum Threshold No
Monitoring Method
Plausibility
Signal Type
pulsating signal
Operating Range
yes/no
Time Length and Frequency for Monitoring/Diagnosis
0.5 sec/permanent
Criteria for storing fault code
fault during 2 trips
Criteria for illuminating the MIL
fault during 2 trips and end of 2nd trip
Criteria used for determining out of range values and input component rationality check
UBATT No
Ground No
Disconnect No
Electronic Control Module (ECM)
Check of minimum sensor output signal. Signals are stored every 240° crank angle. The average of 3 output signals (720° crank angle) is compared to minimum map values (depends on engine speed and load). A fault is detected if the average (measured) value is smaller than the map value.