P0743
System/ComponentTorque Converter clutch
Fault Code
P0743
Fault Type
Plausibility No
Signal Yes
Minimum Threshold Yes
Maximum Threshold Yes
Monitoring Method
Plausibility/check circuit
Signal Type
ECM internal signal/value computation or comparison
Time Length and Frequency for Monitoring/Diagnosis
25 sec/once per ignition key on
Criteria for storing fault code
fault during 2 trips
Criteria for illuminating the MIL
fault during 2 trips and end of 2nd trip
Criteria used for determining out of range values and input component rationality check
UBATT Yes
Ground Yes
Disconnect Yes
Electronic Control Module (ECM)
Fault if (engine speed - calculated turbine speed) is > 288 rpm.