Operation CHARM: Car repair manuals for everyone.

P120A

2FDB - P120A

Information saved in
DME

Fault code
2FDB - P120A

Fault text
Crankcase ventilation, electric ATIC39

Fault description
Crankcase Ventilation Diagnostic Valve Input High

Condition for fault identification
Test condition:
Terminal condition: Terminal 15 on
Voltage condition:
Voltage in onboard electrical system > 10 V

Condition for fault memory entry
90 sec.

Action in service
none

Fault effect and breakdown warning


Driver information
Warning light:
NO

Service instruction
none