DTC 82
Code 82: Calibration Malfunction.:
DTC 82 Calibration Malfunction:
Circuit Description:
This DTC allows the EBCM/EBTCM to check for a calibration failure by comparing the calibration value to a known value stored in the EBCM/EBTCM's memory.
This test is also used as a security measure to prevent improper use of calibrations or changes to these calibrations that may alter the designed function of ABS.
DTC Will Set When:
DTC 82 can be set at ABS initialization. A malfunction exists if the EBCM/EBTCM internal memory calibration is incorrect.
Action Taken:
A malfunction DTC is stored, ABS is disabled and the ABS indicator lamp is turned "ON."
DTC Chart Test Description:
Number(s) below refer to circled number(s) on the diagnostic chart.
1. This step checks to see if the malfunction is present during diagnosis. If present, the EBCM/EBTCM is not functioning correctly and must be replaced.
Diagnostic Aids:
An intermittent DTC 82 is most likely caused by a faulty EBCM/EBTCM that is sensitive to temperature changes. If DTC 82 occurred more than once, but is intermittent, replace EBCM/EBTCM.
The frequency of the malfunction can be checked by using the enhanced diagnostic function of the Tech 1.