Blower Motor: Service and Repair
BLOWER MOTOR REPLACEMENT
REMOVAL PROCEDURE
1. Remove the right side instrument panel insulator.
2. Release the instrument panel harness retainer and move the harness to one side.
3. Disconnect the blower motor electrical connector.
4. Disconnect the blower motor cooling hose.
5. Remove the mounting screws from the blower motor.
6. Remove the blower motor.
INSTALLATION PROCEDURE
1. Install the blower motor.
2. Install the blower motor screws.
Tighten the screws to 1.3 N.m (12 lb in).
NOTE: Refer to Fastener Notice in Service Precautions.
3. Connect the blower motor cooling hose.
4. Connect the blower motor electrical connector.
5. Install the instrument panel harness into the harness retainer.
6. Install the right side instrument panel insulator.