Fuel Gauge: Description and Operation
FUEL GAGE
The IPC displays the fuel level as determined by the PCM. The IPC receives a class 2 message from the PCM indicating the fuel level percent. The fuel gage defaults to empty if:
- The PCM detects a malfunction in the fuel level sensor circuit.
- The IPC detects a loss of class 2 communications with the PCM.
When the fuel level is less than 14% (84ohm), the low fuel indicator illuminates.