Operation CHARM: Car repair manuals for everyone.

Component Tests and General Diagnostics


1. Ensure no continuity between vacuum switch terminal 1 and 2 with vacuum of 6.30 to 7.08 inches Hg applied.
2. Ensure continuity between terminals with no vacuum applied.
3. If results are not as indicated, replace switch.