Troubleshooting Hints - Air Delivery
PERFORM BEFORE BEGINNING SYSTEM DIAGNOSIS1. Check for Manifold Vacuum to the Vacuum Tank at the BLACK hose from the engine and at the VIOLET hose to the Heater and A/C Control Assembly.
2. Check the operation of the Temperature Valve by setting the Temperature Selector first to "COLD" then to "HOT" and back again. The Temperature Valve should move evenly through its full travel each time the temperature setting is changed. If the valve moves unevenly or erratically, check that the valve is not binding at some point.
^ Refer to Blower Motors for HVAC System Check in for a guide to normal operation. Testing and Inspection
^ Refer to System Diagnosis. System Diagnosis