Troubleshooting Hints - Charging System
PERFORM BEFORE BEGINNING SYSTEM DIAGNOSIS:1. Visually inspect the hydrometer (built into Battery).
^ Green dot - Battery is charged.
^ Dark dot - Charge and load test Battery. If Battery passes load test, refer to System Diagnosis. Preliminary Information - Starting System
^ Clear or light yellow dot - Battery electrolyte is low. Replace Battery.
2. Check U/Hood Fuse #8 and I/P Fuse #11. Check Maxifuse 11.
3. Check that the Generator Connector and Generator "BAT" terminal are both clean and tight.
4. Check that the Battery connections are clean and tight.
5. Check Generator belt.
^ Check for a broken (or partially broken) wire inside of the insulation which could cause system failure but prove "GOOD" in a continuity/voltage check (refer to "General Troubleshooting Procedures,"). Diagnostic Aids
^ Check for proper installation of aftermarket electronic equipment which may affect the integrity of other systems (refer to "General Troubleshooting Procedures,").
^ Refer to System Diagnosis.