Torque Converter Clutch Solenoid (TCC)
Important: The TCC solenoid resistance should be 21-26 ohms minimum when measured at 20° C (68° F).
If a fault is detected in the TCC solenoid circuit code P0740 will set.
The torque converter clutch solenoid valve is a normally open exhaust valve that is used to control torque converter clutch apply and release. When grounded (energized) by the PCM, the TCC solenoid valve stops converter signal oil from exhausting. This causes converter signal oil pressure to increase and shifts the TCC solenoid valve into the apply position.
The brake switch is an input to the PCM, and the PCM directly controls the TCC apply based on the brake switch status.