Turn Lamps
With the Ignition Switch in RUN, BULB TEST or START, voltage is applied from Fuse 30 to the normally closed pole of the Hazard Switch in the
Turn Signal Switch through CKT 539. which feeds the Turn/Hazard Flasher Module through CKT 1508. With the Turn Signal Switch in the Turn Left position, voltage is applied from the Turn Signal Switch to CKT 14 at terminal A2 of connector C201 and to CKT 18 at terminal A4 of C201. LH Front Turn, Rear Turn and Indicator Lamps flash ON and OFF as current flow heats the timing element in the Turn Flasher, and it continuously opens and closes the circuit (for RH Turn Lamps. CKT 15 terminal A3 of C201 and CKT 19 terminal A5 of C201). With Park Lamps ON and Turn Lamps ON, voltage is applied to both terminals of the Front Side Marker Lamp causing it to be OFF. When the Front Turn Lamp is OFF, voltage is applied to only one terminal of the