Operation CHARM: Car repair manuals for everyone.

Amperage

Brush Length Standard 16 mm (0.63 in)
Brush Length Limit (Minimum) 2 mm (0.08 in)
Condenser Capacity 0.5 microfarads
Direction of Rotation Clockwise (Pulley Side)
Maximum Generator Output 55 amps
Maximum Generator Speed 18,000 RPM
Normal Operating Voltage 12 volts
Polarity Negative (-) Ground No-Load Generator Speed 1,100 RPM
Regular Voltage 14.7-15.0 volts
Temperature Range 30 to 80°C (-22 to 170°F)