Scan Tool Data Definitions
8 DIGIT GM PART NUMBER: The scan tool displays an 8 digit alphanumeric number. The part number of the module.COMMANDED GEN: The scan tool displays Disabled until the generator is commanded ON by the PCM.
COMMANDED STARTER: The scan tool displays Disabled until the starter is commanded ON by the PCM.
GENERATOR PWM: The scan tool displays the % time that the generator is ON.
LOAD MANAGEMENT STATUS: The scan tool displays Inactive until the Load Management System is commanded ON by the BCM.
STARTER ENABLED RELAY: The scan tool displays OK unless there is an open on the coil side of the relay, then fault is displayed.