Headlight Doors
Battery Positive voltage is applied from the HDLP circuit breaker in the instrument panel fuse block to both the coil and switch side of the ALC HDLP relay 44. When the BCM receives this signal it will apply a ground to the coil side of the ALC HDLP relay 44. This energizes the relay, closing the switch, and applies battery positive voltage to the
headlamp switch and to the