Operation CHARM: Car repair manuals for everyone.

Blower Motor Control Processor Replacement

REMOVAL PROCEDURE




1. Remove the IP lower insulator panel - RH.

CAUTION: Unplug the blower motor before removal. Blower motor case contact with any ground may start the fan and cause personal injury

2. Disconnect the blower motor control module electrical connector.




3. Disconnect the blower motor control module electrical connector from the blower motor.




4. LOOSEN the blower motor control module forward two retaining screws (nearest the dash mat) approximately 5 mm (0.197 in).
The control module is slotted at the forward retaining locations.
5. Remove the rear blower motor control module retaining screw.
6. Tilt down the rear of the blower motor control module.
7. Remove the blower motor control module from the HVAC module.

INSTALLATION PROCEDURE




1. Install the blower motor control module to the HVAC module.
2. Position the blower motor control module forward retaining slots onto the forward retaining screws.
3. Align and seat the blower control module to the HVAC module.
4. Install the rear blower motor control module retaining screw.

NOTE: Refer to Fastener Notice in Service Precautions.

5. Tighten all the blower motor control module retaining screws.

Tighten
Tighten the screws to 1.6 N.m (14 lb in).




6. Connect the blower motor electrical connector.




7. Connect the blower motor control module electrical connector.
8. Install the IP lower insulator panel - RH.