HVAC Control Processor Replacement
REMOVAL PROCEDURE1. Remove the IP lower insulator panel RH.
2. Disconnect the blower motor electrical connector.
3. Disconnect the blower control module electrical connector.
4. LOOSEN the blower control module forward two retaining screws (nearest the dash mat) approximately 5 mm (0.197 in).
The blower control module is slotted at the forward retaining locations.
5. Remove the blower control module rear retaining screw.
6. Tilt down the rear of the blower control module.
7. Remove the blower control module from the vehicle.
INSTALLATION PROCEDURE
1. Position the blower control module forward retaining slots onto the forward retaining screws.
2. Align and seat the blower control module to the HVAC module.
3. Install the blower control module rear retaining screw.
NOTE: Refer to Fastener Notice in Service Precautions.
4. Tighten the blower control module retaining screws.
Tighten
Tighten the screws to 1.6 N.m (14 lb in).
5. Connect the blower motor electrical connector.
6. Connect the blower control module electrical connector.
7. Install the IP lower insulator panel - RH.