Instrument Panel Cluster (IPC) - Replacement
INSTRUMENT PANEL CLUSTER (IPC) REPLACEMENT
REMOVAL PROCEDURE
1. Remove the instrument panel (I/P) cluster trim panel.
2. Remove the screws (6) from the top of the I/P cluster (5).
3. Remove the I/P cluster (5) pulling rearward.
4. Disconnect the electrical connector (1) from the I/P cluster (5).
5. Remove the I/P cluster (5) from I/P (3).
INSTALLATION PROCEDURE
1. Connect the electrical connector (1) to the I/P cluster (5).
2. Position the I/P cluster retainer tabs (4) into the I/P (3).
3. Install the instrument panel cluster (5) to the I/P (3).
4. Install the I/P cluster screws (6).
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten the screws to 2 N.m (18 lb in).
5. Install the I/P cluster trim panel.