Air Cleaner Housing: Service and Repair
Air Cleaner Assembly Replacement
Removal Procedure
1. Disconnect the electrical connector for the mass air flow/intake air temperature sensor (MAF/IAT) (1).
2. Remove the connection for the IAT sensor (2).
3. Loosen the clamps (3).
4. Remove the air intake duct (4).
5. Remove the MAF/IAT sensor (5).
6. Remove the air cleaner assembly (6).
Installation Procedure
1. Install the air cleaner assembly (6).
2. Install the MAF/IAT sensor (5).
3. Install the air intake duct (4).
4. Tighten the clamps (3).
5. Install the connection for the IAT sensor (2).
6. Reconnect the electrical connector (1).