Operation CHARM: Car repair manuals for everyone.

Blower Motor Control Module Replacement (LHD)




Blower Motor Control Module Replacement (LHD)

Removal Procedure

1. Remove the temperature valve actuator-right side. Refer to Temperature Valve Actuator Replacement - Right Side (LHD) Temperature Valve Actuator Replacement - Right Side (LHD).





2. Disconnect the blower motor control processor electrical connector (1).

3. Remove the blower motor control processor to HVAC module assembly retaining screws (4).

4. Remove the blower motor control processor (3) from the HVAC module assembly (2).

Installation Procedure





1. Install the blower motor control processor (3) to the HVAC module assembly (2).

Caution:
Refer to Fastener Caution Fastener Caution.

2. Install the blower motor control processor to HVAC module assembly retaining screws (4) and tighten to 1 Nm (9 lb in).

3. Connect the blower motor control processor electrical connector (1).

4. Install the temperature valve actuator-right side. Refer to Temperature Valve Actuator Replacement - Right Side (LHD) Temperature Valve Actuator Replacement - Right Side (LHD).