Component Tests and General Diagnostics
Fig.19 - Dual Breaker Point Distributor System Troubleshooting Chart:
Fig.20 - Dual Breaker Point Distributor System Troubleshooting Chart:
System Testing
Testing of this system is accomplished by performing a continuity test on the distributor relay. Disconnect lead wire from distributor relay terminal (retarded contact breaker points) and connect tester to terminal and ground. Turn ignition switch on (engine off) and follow procedure shown in Figs. 19 and 20.