Troubleshooting Hints - Starting System
PERFORM THESE STEPS FIRSTStarter
1. Visually inspect the hydrometer (built into Battery).
^ Green eye - Battery is charged.
^ Dark eye - Charge and load test Battery, If Battery passes load test, refer to "System Diagnosis," Preliminary Information - Starting System
2. Check that Starter Solenoid terminals "S" and "B" and battery connections are clean and tight.
3. Check that Fusible Links B and W are undamaged.
4. Check that G100 is clean and tight.
^ Check for a broken (or partially broken) wire inside of the insulation which could cause system failure but prove "GOOD" in a continuity/voltage check.
^ Check for proper installation of aftermarket electronic equipment which may affect the integrity of other systems.
^ Refer to System Diagnosis. Preliminary Information - Starting System
Charging System
1. Visually inspect the hydrometer (built into Battery).
^ Green eye - Battery is charged.
^ Dark eye - Charge and load test Battery.
^ Clear or light yellow eye - Battery electrolyte is low. Replace Battery.
2. Check IGN Fuse.
3. Check that the Generator connector and Generator "BAT" terminal are clean and tight.
4. Check that the Starter Solenoid terminal "B" is clean and tight.
5. Check that Fusible Link H is undamaged.
6. Check Generator Belt.
7. Check that battery connections are clean and tight.