B1071
Circuit Description
DTC B1071 is an indication of a potential internal inflatable restraint Sensing and Diagnostic Module (SDM) malfunction. DTC B1071 will set upon detection of any condition in the table below.
Conditions for Setting the DTC
Action Taken When the DTC Sets
^ The SDM sets a Diagnostic Trouble Code.
^ The SDM turns ON the AIR BAG warning lamp.
Conditions for Clearing the DTC
^ Current DTC- The malfunction has not been detected for 500 milliseconds.
^ History DTC
- You issue a scan tool CLEAR CODES command.
- Once 250 malfunction free ignition cycles have occurred.
Diagnostic Aids
When you issue a scan tool CLEAR CODES command, some of the indicated malfunctions will only allow the AIR BAG warning lamp to go out briefly then come back ON.
When measurements are requested in this table, use the J 39200 Digital Multimeter with the correct terminal adapter from the J 35616-A Connector Test Adapter Kit. When an inspection for proper connection is requested, refer to Intermittents and Poor Connections. When a wire, connector or terminal repair is requested, use the J 38125-B Terminal Repair Kit. Refer to Wiring Repair. SIR Wiring Repair Intermittent Problems
Notice: When DTC B1018 or B1024 has been set it is necessary to replace the inflatable restraint Sensing and Diagnostic Module (SDM). Setting DTC B1018 or B1024 will also cause DTC B1071 to set. When a scan tool clear codes command is issued and the malfunction is no longer present, DTC B1018 or B1024 and DTC B1071 will remain current. Make sure that the short to ground condition is repaired prior to installing a replacement SDM to avoid damaging the SDM.