Refrigerant Pressure Sensor / Switch: Service and Repair
REMOVAL PROCEDURE
1. Remove the air cleaner cover and duct assembly.
2. Disconnect the electrical connector from the A/C pressure sensor.
3. Remove the A/C pressure sensor from the liquid line.
INSTALLATION PROCEDURE
1. Using a lint-free clean, dry cloth, carefully clean the sealing surfaces of the liquid line fitting.
2. Lightly coat the new O-ring seal with mineral base 525 viscosity refrigerant oil.
IMPORTANT: DO NOT allow any of the mineral base 525 viscosity refrigerant oil on the new O-ring seal to enter the refrigerant system.
3. Install the new O-ring seal.
NOTE: Refer to Fastener Notice in Service Precautions.
4. Install the A/C pressure sensor to the liquid line.
Tighten
Tighten the switch to 5 N.m (44 lb in).
5. Connect the electrical connector to the A/C pressure sensor.
6. Install the air cleaner and duct assembly.