Control Assembly: Service and Repair
Control Assembly Replacement
Removal Procedure
1. Remove the bezel assembly screws from the instrument panel cluster.
2. Remove the bezel assembly for the instrument panel cluster from the instrument panel.
3. Remove the HVAC control assembly screws.
4. Remove the HVAC control assembly from the instrument panel.
5. Disconnect the electrical connections.
Installation Procedure
1. Connect the electrical connections.
2. Install the HVAC control assembly to the instrument panel.
Notice: Refer to Fastener Notice in Cautions and Notices.
3. Install the HVAC control assembly screws.
Tighten the HVAC control assembly screws to 2 Nm (18 lb in).
4. Install the bezel assembly for the instrument panel cluster.
5. Install the bezel assembly screws for the instrument panel cluster.
Tighten the instrument panel cluster bezel assembly screws to 2 Nm (18 lb in).
6. Inspect the circuit operation.