Fuel Gage Inaccurate or Inoperative (Single Tank)
Fuel Gage Inaccurate or Inoperative (Single Tank)
Diagnostic Aids
* Ensure that the fuel level is in the same range as the customer concern.
* For intermittent diagnosis, refer to Testing for Intermittent Conditions and Poor Connections Testing for Intermittent Conditions and Poor Connections.
* Use the fuel sender resistance (0-90 ohms) to verify the fuel level sender operation. When the fuel tank is empty the sender resistance is 0 ohms and when the fuel tank is full the sender resistance is 90 ohms.