Generator Noise Test
Noise from a generator may be caused by any of the following:^ A loose drive pulley
^ Loose mounting bolts
^ Worn or dirty bearings
^ A defective diode
^ A worn stator
A high frequency whine or magnetic noise may be heard at full output. This is a normal condition. Perform a generator output test in order to help distinguish bearing noise from magnetic noise or whine. Refer to Battery Inspection/Test. Battery Inspection/Test
A growling noise under a high load condition could indicate a shorted bridge diode. A generator with a shorted diode will also have a reduced output. Perform a generator output test. Refer to Battery Inspection/Test Battery Inspection/Test
It is also helpful to listen to the generator under a moderate load (i.e. headlights ON) in order to determine if there is a bearing or magnetic noise.
Do not disassemble the CS130D generator. Generator service is limited to replacement only. Refer to Generator Replacement.