Alarm Switch Replacement
Alarm Switch ReplacementRemoval Procedure
1. Disconnect the electrical connector from the fluid pressure alarm switch.
2. Remove the fluid pressure alarm switch from the vehicle by rotating the switch in a counter clockwise direction.
Installation Procedure
Notice: Refer to Fastener Notice in Service Precautions.
1. Install the fluid pressure alarm switch to the vehicle.
Tighten the fluid pressure alarm switch to 12 Nm (106 inch lbs.).
2. Connect the electrical connector to the fluid pressure alarm switch.