Instrument Cluster / Carrier: Service and Repair
INSTRUMENT PANEL CLUSTER (IPC) REPLACEMENT
REMOVAL PROCEDURE
1. Remove the instrument panel (I/P) center trim panel.
2. Remove 4 screws that retain the cluster bezel to the I/P.
3. Partially remove the cluster bezel to gain access to the electrical connections.
4. Disconnect the electrical connections.
INSTALLATION PROCEDURE
1. Connect the electrical connections.
2. Install the cluster bezel into the I/P opening.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten the screws to 2.5 N.m (22 lb in).
3. Install the 4 screws that retain the cluster bezel to the I/P.
4. Install the I/P center trim panel.