Operation CHARM: Car repair manuals for everyone.

Energy Storage Box (ESB) 120V Receptacle Face Plate Replacement



ENERGY STORAGE BOX (ESB) 120V RECEPTACLE FACE PLATE REPLACEMENT

REMOVAL PROCEDURE




1. Remove the energy storage box (ESB) intermediate cover.
2. Disconnect the 120-volt AC electrical connector (3).




3. Remove the receptacle outlet screws (1).




4. Carefully pull the receptacle outlet (3) out of the ESB until the retaining tabs are accessible.
5. Insert a small flat-bladed tool into the openings (1) in the receptacle box in order to release the tabs securing the face plate.
6. Remove the receptacle face plate (2).

INSTALLATION PROCEDURE




1. Position the receptacle face plate (2) to the receptacle box (3).
2. Push inward until the retaining tabs lock into the openings (1) in the receptacle box.




3. Install the receptacle box (2) into the ESB.

NOTE: Refer to Fastener Notice in Service Precautions.

4. Install the receptacle outlet screws (1).

Tighten the screws to 0.5 N.m (4.4 lb in).




5. Connect the 120-volt AC electrical connector (3).
6. Install the ESB intermediate cover.