Energy Storage Box (ESB) Service Disconnect Power Cable to Fuse Replacement
ENERGY STORAGE BOX (ESB) SERVICE DISCONNECT POWER CABLE TO FUSE REPLACEMENT
REMOVAL PROCEDURE
1. Remove the service disconnect power cable.
2. Remove the maxi-fuse.
3. Cut the tie straps securing the power cable to the energy storage box (ESB).
4. Remove the service disconnect power cable nut at the service disconnect switch.
5. Remove the service disconnect power cable from the fuse holder and service disconnect switch.
INSTALLATION PROCEDURE
1. Install the service disconnect power cable to the fuse holder and service disconnect switch.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the service disconnect power cable nut at the service disconnect switch.
Tighten the nut to 10 N.m (89 lb in).
3. Install NEW tie straps securing the power cable to the ESB.
4. Install the maxi-fuse.
5. Install the service disconnect power cable.