P0AE7
DTC P0AE7
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle (with HP2) (Initial Inspection and Diagnostic Overview)Diagnostic System Check - Vehicle (without HP2) (Initial Inspection and Diagnostic Overview) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Initial Inspection and Diagnostic Overview) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Initial Inspection and Diagnostic Overview) provides an overview of each diagnostic category.
DTC Descriptor
DTC P0AE7
- Hybrid Battery Precharge Contactor Control Circuit High Voltage
Diagnostic Fault Information
Circuit/System Description
The hybrid drive motor generator battery contains 3 high voltage contactor relays also referred to as high voltage (HV) relays. The HV relays allow the high voltage DC batteries to be connected to the vehicle or safely contain the DC high voltage within the drive motor generator battery assembly. The three HV relays are a positive HV contactor relay, negative HV contactor relay, and current limit relay. These relays/contactors close and open in a certain sequence and are controlled by the BECM. The control circuit for the HV relays use a wire from the relay to case ground and the BECM supplies voltage to turn them on and off individually. The BECM monitors the control circuit voltage to these relays and 12 V reference circuit internal to the control module to determine if the circuit is open by comparing the two voltage readings. If the BECM detects 2 consecutive failed high voltage precharge events, a precharge wait time is activated by the BECM. This precharge wait time limit is to allow the precharge circuit internal to the drive motor generator battery assembly to cool down. The precharge wait time counts down in seconds and is displayed on the scan tool.
Conditions for Running the DTC
* The ignition is ON.
* The 12 V battery voltage is 9-18 V.
* The current limit relay is commanded open.
Conditions for Setting the DTC
The BECM compares the High Voltage current limit relay control circuit to the BECMs internal 12 V measurement reference circuit. This DTC sets when the high voltage current limit relay control circuit voltage and the BECMs internal voltage reference are within 2 V of each other when the current limit relay is commanded open.
Action Taken When the DTC Sets
After 2 failed high-voltage precharge events, a 20-40 minute precharge wait time is activated by the BECM.
Conditions for Clearing the DTC
DTC P0AE7 is a type C DTC.
Reference Information
Schematic Reference
Hybrid Energy Storage Schematics (Electrical Diagrams)
Connector End View Reference
Component Connector End Views (Connector Views)
Description and Operation
Drive Motor Battery System Description (Drive Motor Battery System Description)
Electrical Information Reference
* Circuit Testing (Component Tests and General Diagnostics)
* Connector Repairs (Component Tests and General Diagnostics)
* Testing for Intermittent Conditions and Poor Connections (Component Tests and General Diagnostics)
* Wiring Repairs (Component Tests and General Diagnostics)
DTC Type Reference
Powertrain Diagnostic Trouble Code (DTC) Type Definitions (Diagnostic Trouble Code Descriptions)
Scan Tool Reference
Control Module References (Programming and Relearning) for scan tool information
Special Tools
EL-48900 HEV Safety Kit
Circuit/System Verification
Ignition ON, command the HV current limit relay open and closed with a scan tool. Listen the for the relay clicks.
Circuit/System Testing
Danger: Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed.
The High Voltage Disabling procedure will perform the following tasks:
* Identify how to disable high voltage.
* Identify how to test for the presence of high voltage.
* Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must be followed.
Failure to follow the procedures exactly as written may result in serious injury or death.
1. Ignition OFF, disable the high voltage at the drive motor generator battery. Refer to High Voltage Disabling (High Voltage Disabling).
2. Remove the drive motor generator battery cover. Refer to Drive Motor Battery Case Upper Cover, Front Cover, and Right Side Cover Replacement (Drive Motor Battery Case Upper Cover, Front Cover, and Right Side Cover Replacement).
3. Disconnect the X1 and X2 connectors at the current limit relay.
4. Ignition OFF, test for less than 5 Ohms between the ground circuit terminal 6 X2 and ground.
• If greater than the specified range, test the ground circuit for an open/high resistance.
5. Connect the 12 V battery.
6. Connect a test lamp between the control circuit terminal 5 X1 and the ground circuit terminal 6 X2.
7. Command the Precharge Contactor open and closed with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
• If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the drive motor generator battery control module.
• If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the drive motor generator battery control module.
8. If all circuits test normal, test or replace the current limit relay.
Component Testing
Danger: Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed.
The High Voltage Disabling procedure will perform the following tasks:
* Identify how to disable high voltage.
* Identify how to test for the presence of high voltage.
* Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must be followed.
Failure to follow the procedures exactly as written may result in serious injury or death.
1. Ignition OFF, disable the high voltage at the drive motor generator battery. Refer to High Voltage Disabling (High Voltage Disabling).
2. Remove the drive motor generator battery cover. Refer to Drive Motor Battery Case Upper Cover, Front Cover, and Right Side Cover Replacement (Drive Motor Battery Case Upper Cover, Front Cover, and Right Side Cover Replacement).
3. Disconnect the X1 and X2 harness connectors at the current limit relay.
4. Test for 60-70 Ohms at 20°C (68°F) between the control terminal 5 X1 and the ground terminal 6 X2 of the current limit relay.
• If not within the specified range, replace the current limit relay.
Repair Instructions
Perform the Diagnostic Repair Verification (Verification Tests) after completing the repair.
* Drive Motor Power Inverter Current Limit Relay Replacement (Drive Motor Power Inverter Current Limit Relay Replacement)
* Control Module References (Programming and Relearning) - for drive motor generator battery control module replacement, setup and programming.