1, 2 and 3 Digit Codes: 105
Scan Tool 105 (MIL 21):
Trouble Code Number
- Scan tool 105
- General scan tool P0141
- MIL 21
Fault Message
- Downstream HO2S Heater Failure
Background
- The PCM continues to monitor this system after the key is OFF.
- The PCM waits some periods to allow the heated oxygen sensors to cool.
- Once the PCM calculates that the heated oxygen sensor is cooled, it energizes the MFI relay (ASD relay) and tests for the heated oxygen sensor operation.
Range of Check
- 5 seconds or more after turning the ignition switch to OFF.
- Battery positive voltage: 10 V or more
- The heated oxygen sensor output line voltage rises by 0.49 V or more within 144 seconds after turning the ignition switch to OFF.
- The initial rise of the output line voltage is less than 1.57 V.
Set Condition
- Heated oxygen sensor circuit does not show the appropriate decrease of voltage during the test.
Probable Cause
- Heated oxygen sensor heater open circuit
- Wiring harness and connectors failed