Right SIACM Curtain Squib Circuit Shorted (Stored)
Test 1:
Test 2:
SYMPTOM
RIGHT SIACM, CURTAIN SQUIB CIRCUIT SHORT - STORED
TEST NOTE
This symptom is diagnosed using the test ORC, INTERROGATE RIGHT SIACM - STORED.
WHEN MONITORED
When the ignition is ON, the Right SIACM monitors the resistance of the Right Curtain Squib circuits.
SET CONDITION
The Right SIACM has detected that the Right Curtain Squib circuits are shorted together.
POSSIBLE CAUSES
- Checking for active AOSIM DTCS
- Checking for active right SIACM DTCS
- Stored code present