Variable Induction Control Valve: Service and Repair
REMOVAL1. Disconnect negative battery cable.
Fig. 21 Manifold Tuning Valve:
2. Disconnect electrical connector (Fig. 21).
Fig. 22 Manifold Tuning Valve Removal/Installation:
3. Remove manifold tuning valve mounting screws. Remove tuning valve (Fig. 22).
INSTALLATION
1. Install tuning valve. Tighten mounting screws to 11.9 Nm (105 in. lbs.) torque.
2. Install electrical connector.
3. Connect negative battery cable.