Battery Power to Module Disconnected
Tests 1 - 4:
SYMPTOM
BATTERY POWER TO MODULE DISCONNECTED
WHEN MONITORED
Continuously.
SET CONDITION
This code detects if the IOD fuse/connector is not supplying power to the BCM.
POSSIBLE CAUSES
- Open fused B+ circuit
- Body control module
- Wiring harness intermittent defect