P1799
SYMPTOM
P1799 - CALCULATED OIL TEMP IN USE
WHEN MONITORED:
Whenever the engine is running. The code is set if any of the following conditions exist for three consecutive key starts: The thermistor voltage is out of range (below 0.70 volts or greater than 4.94 volts)
SET CONDITION
If continuous erratic thermistor voltage is sensed. The thermistor temperature stays below 80 °F for an extended period time.
POSSIBLE CAUSES
- INTERMITTENT WIRING AND CONNECTORS
- SPEED SENSOR GROUND CIRCUIT OPEN
- TRANSMISSION TEMPERATURE SENSOR SIGNAL CIRCUIT OPEN
- TRANSMISSION TEMPERATURE SENSOR SIGNAL CIRCUIT SHORT TO GROUND
- SPEED SENSOR GROUND CIRCUIT SHORT TO VOLTAGE
- TRANSMISSION TEMPERATURE SENSOR SIGNAL CIRCUIT SHORT TO VOLTAGE
- TRANSMISSION TEMPERATURE SENSOR
- TCM - TRANSMISSION TEMPERATURE SENSOR LOW
- TCM - TRANSMISSION TEMPERATURE SENSOR HIGH