Amplifier: Service and Repair
REMOVALNOTE: A battery reconnect procedure must be performed anytime the battery has been disconnected.
1. Disconnect and isolate battery negative cable.
2. Remove the instrument panel silencer.
3. Disconnect electrical harness connectors.
4. Remove the mounting fasteners (1).
5. Remove the amplifier (2).
INSTALLATION
NOTE: A battery reconnect procedure must be performed anytime the battery has been disconnected.
1. Position amplifier (2) into place.
2. Install mounting fasteners (1).
3. Connect electrical harness connectors.
4. Install instrument panel silencer.
5. Connect battery negative cable.