Driver Rear Window Switch MUX Input Stuck - DDM
Test 1 - 2:
Test 3:
SYMPTOM
DRIVER REAR WINDOW SWITCH MUX INPUT STUCK - DDM
WHEN MONITORED
Continuously.
SET CONDITION
If the voltage on the Driver Rear Window Switch MUX circuit is between 0.6 and 4.4 volts for over 15 seconds, this code will set.
POSSIBLE CAUSES
- DTC present
- Rear switch
- Driver rear window switch MUX circuit partial short to ground.
- Driver door module